Added November 22, 2019 by Asbjoern
2nd aux radiator was turned off during the second log. Weather at the time of logging: Day, clear 26C / 79F indicated in cluster 25C / 77F indicated on weather app 36% rH humidity on weather app 1011mb pressure on weather app almost no wind not far from sea-level. First test: All coolers on + WI: Peak iat 111F 44C Peak dct 217F 103C Peak oil 262F 128C Peak coolant 223F 106C Second test: As test number 1, but with the 2nd aux radiator turned off: Peak iat 111F 44C Peak dct 210F 99C Peak oil 262F 128C Peak coolant 228F 109C
2nd aux radiator was turned off during the second log. Weather at the time of logging: Day, clear 26C / 79F indicated in cluster 25C / 77F indicated on weather app 36% rH humidity on weather app 1011mb pressure on weather app almost no wind not far from sea-level. First test: All coolers on + WI: Peak iat 111F 44C Peak dct 217F 103C Peak oil 262F 128C Peak coolant 223F 106C Second test: As test number 1, but with the 2nd aux radiator turned off: Peak iat 111F 44C Peak dct 210F 99C Peak oil 262F 128C Peak coolant 228F 109C